Building components- external wall - awmihi01b Source: Saint-Gobain Rigips Austria GesmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update28.09.2017/hfa.plb
external wall: solid wood construction, ventilated, with dry lining, with cladding

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 19.0 larch wood external wall cladding  0,155  50  600  1,600   D
 40.0 spruce wood battens (40/60)  0,120  50  450  1,600   D
 22.0 softboard [047; 240]   0,047  3 - 7  240  2,100   E
*   softboard [040; 125]   0,040  3 - 7  125  2,100   E
*   cross laminated timber BBS   0,130  50  470  1,600   D
 70.0 spruce wood battens (60/60; e=625) mounted on resilient clips  0,120  50  450  1,600   D
 50.0 mineral wool [040; 18]   0,040  18  1,030   A1
 25.0 gypsum plasterboards Rigips RF (2x12,5 mm) or  0,250  10  900  1,050   A2
 25.0 gypsum fibre board Rigidur H (2x12,5 mm)  0,350  19  1200  1,100   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  D* E* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   140,0  90,0  406,0  BBS 3 layer
 
60  0,16  26,3  adequate  –  59(-3,-11)  4,9  104,6   awmihi01b-00  
 
01   140,0  100,0  416,0  BBS 5 layer
 
90  0,16  26,3  adequate  –  59(-3,-11)  4,9  109,3   awmihi01b-01  
 
02   200,0  90,0  466,0  BBS 3 layer
 
60  0,13  26,3  adequate  –  59(-3,-11)  -10,1  112,1   awmihi01b-02  
 
03   200,0  100,0  476,0  BBS 5 layer
 
90  0,13  26,3  adequate  –  59(-3,-11)  -10,1  116,8   awmihi01b-03