Building components- external wall - awmohi02a
 
 


Cross-section of standard configuration
[Additional views]

note:
Cross laminated timber:
Variation 00-02: d ≥ 94,0; at least 3-layers, top layer at least 30mm; variation 03: d ≥ 85,0; at least 5-layers, top layer at least 17mm


Last update11.05.2017/hfa.plb
external wall: solid wood construction, ventilated, with dry lining, with cladding

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 20.0 larch wood external wall cladding  0,150  50  600  1,600   D
 30.0 spruce wood battens (30/60)  0,120  50  450  1,600   D
  vapour-permeable membrane sd ≤ 0,3m           
 15.0 gypsum fibre board   0,320  21  1000  1,100   A2
 200.0 finger-jointed solid construction timber (60/200; e=625)  0,120  50  450  1,600   D
*   Insulation material            
*   cross laminated timber   0,130  50  500  1,600   D
*   x   0,120  50  450  1,600   
*   Exchangeable layer          
 12.5 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 12.5 gypsum fibre board   0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  F* G* H* I* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   200,0  94,0  60,0  50,0  431,5  three-ply cross laminated timer
I=mineral wool [040; 13] 
90  0,15  16,4  adequate  –  53(-2,-8)  -3,0  107,5   awmohi02a-00  
F = wood-fibre insulation board [0,039; r>5]
01   200,0  94,0  60,0  50,0  431,5  three-ply cross laminated timer
I=mineral wool [040; 13] 
90  0,15  16,4  adequate  –  48(,)  0,0  100,5   awmohi02a-01  
F = mineral wool [R=11; r>5]
02   200,0  94,0  60,0  50,0  431,5  three-ply cross laminated timer
I=cellulose fibre [0,040; R=50] 
90  0,15  16,4  adequate  –  53(,)  -10,0  109,2   awmohi02a-02  
F = cellulose fibre [R=50; r>5]
03   200,0  85,0  60,0  50,0  422,5  five-ply cross laminated timer
I=mineral wool [040; 13] 
60  0,16  16,5  adequate  –  47(,)  -4,0  96,0   awmohi02a-03  
F = mineral wool [R=11; r>5]