Building components- external wall - awmoho05a
 
 


Cross-section of standard configuration
[Additional views]

note:
Cross laminated timber:
Variation 00-01: d ≥ 94,0; at least 3-layers, top layer at least 30mm; variation 02: d ≥ 85,0; at least 5-layers, top layer at least 17 mm


Last update28.09.2017/hfa.plb
external wall: solid wood construction, ventilated, without dry lining, with cladding

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 20.0 larch wood external wall cladding  0,155  50  600  1,600   D
 30.0 spruce wood battens  0,120  50  450  1,600   D
  vapour-permeable membrane sd ≤ 0,3m           
 15.0 gypsum fibre board   0,320  21  1000  1,100   A2
*   Insulation material            
*   cross laminated timber   0,130  50  500  1,600   D
*   Exchangeable layer          
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  E* F* G* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   200,0  94,0    359,0  null
 
60  0,17  39,8  adequate  –  43(,)  24,0  107,4   awmoho05a-00  
wood-fibre insulation board [0,040; R=160]
01   200,0  94,0    359,0  null
 
60  0,15  39,9  adequate  –  41(,)  42,0  101,4   awmoho05a-01  
mineral wool [035; 130]
02   200,0  85,0  13,0  362,5  D=2x60 mm
G=gypsum plasterboards with improved properties at high temperatures (fire)/Gypsum fibre board 
60  0,15  40,4  adequate  –  43(,)  44,0  96,9   awmoho05a-02  
mineral wool [035; 130]