Building components- external wall - awmopi01a
 
 


Cross-section of standard configuration
[Additional views]

Last update23.03.2017/hfa.plb
external wall: solid wood construction, not ventilated, with dry lining, with rendering

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
*   plaster   1,000  10 - 35  2000  1,130   A1
*   Insulation materialplaster substitute            
*   cross laminated timber   0,130  50  500  1,600   D
 70.0 spruce wood battens (50/40) mounted on resilient clips  0,120  50  450  1,600   D
 50.0 Exchangeable layer          
 12.5 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 12.5 gypsum fibre board   0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  A* B* C* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   4,0  120,0  97,0  303,5  E=glass wool [0,0040; R=16]  120  0,20  16,6  adequate  –  49(,)  28,5  86,2   awmopi01a-00  
B = mineral wool MW-PT
01   4,0  120,0  97,0  303,5  E=mineral wool [0,041; R=27]  120  0,20  16,6  adequate  –  47(,)  28,8  87,0   awmopi01a-01  
B = mineral wool MW-PT
02   4,0  140,0  97,0  323,5  E=glass wool [0,0040; R=16]  120  0,18  16,6  adequate  –  49(,)  35,2  89,2   awmopi01a-02  
B = mineral wool MW-PT
03   4,0  140,0  97,0  323,5  E=mineral wool [0,040; R=28]  120  0,18  16,6  adequate  –  47(,)  35,2  90,0   awmopi01a-03  
B = mineral wool MW-PT
04   7,0  100,0  97,0  286,5  E=glass wool [0,0040; R=16]  120  0,26  16,6  adequate  –  42(,)  24,1  93,2   awmopi01a-04  
B = wood-fibre insulation board
05   15,0  100,0  97,0  312,5  E=glass wool [0,0040; R=16]  120  0,25  16,6  adequate  –  50(,)  39,2  108,7   awmopi01a-05  
B = multilayer wood wool composite board (WW-MW-WW)
06   7,0  160,0  94,0  343,5  null
E=glass wool [0,0040; R=16] 
90  0,17  16,5  adequate  –  48(,)  35,0  105,0   awmopi01a-06  
B = wood-fibre insulation board [0,045; R=190]
07   4,0  180,0  94,0  360,5  null
E=glass wool [0,0040; R=16] 
90  0,14  16,5  adequate  –  49(,)  43,0  92,0   awmopi01a-07  
B = mineral wool MW-PT [035; R=130]
08   4,0  180,0  85,0  351,5  null
E=glass wool [0,0040; R=16] 
60  0,14  16,5  adequate  –  49(,)  42,0  87,5   awmopi01a-08  
B = mineral wool MW-PT [035; R=130]