Building components- external wall - awmopi02a Source: Saint-Gobain Rigips Austria GesmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update28.09.2017/hfa.plb
external wall: solid wood construction, not ventilated, with dry lining, with rendering

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 6.0 plaster   1,000  10 - 35  2000  1,130   A1
 60.0 wood-fibre insulation board [0,046; R=200]   0,046  3 - 7  200  2,100   E
 160.0 finger-jointed solid construction timber (60/160; e=625)  0,120  50  450  1,600   D
 160.0 mineral wool [035; 18]   0,035  18  1,030   A1
 90.0 cross laminated timber BBS 3 layer  0,130  50  470  1,600   D
 70.0 spruce wood battens (60/60; e=625) mounted on resilient clips  0,120  50  450  1,600   D
 50.0 mineral wool [040; 18]   0,040  18  1,030   A1
 15.0 gypsum plasterboards Rigips RF or  0,250  10  900  1,050   A2
 15.0 gypsum fibre board Rigidur H   0,350  19  1200  1,100   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   401,0    60  0,14  19,2  adequate  –  55(-7,-15)  8,4  93,8   awmopi02a-00