Building components- external wall - awmopo01a
 
 


Cross-section of standard configuration
[Additional views]

note:
Cross laminated timber:
Variation 00-03: d ≥ 78,0; at least 3-layers, top layer at least 25 mm; variation 04-05: d ≥ 94,0; at least 3-layers, top layer at least 30 mm


Last update22.06.2017/hfa.plb
external wall: solid wood construction, not ventilated, without dry lining, with rendering

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
*   plaster   1,000  10 - 35  2000  1,130   A1
*   Insulation material            
*   solid wood (e.g. cross laminated timber)  0,130  50  500  1,600   D
*   Exchangeable layer          
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  A* B* C* D* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   4,0  120,0  78,0  13,0  214,5  D=gypsum fibre board  60  0,25  44,7  adequate  –  38(-1,-4)  23,1  83,5   awmopo01a-00  
B = mineral wool MW-PT
01   4,0  140,0  78,0  13,0  234,5  D=gypsum fibre board  60  0,23  44,8  adequate  –  39(-1,-4)  29,5  86,5   awmopo01a-01  
B = mineral wool MW-PT
03   15,0  100,0  78,0  13,0  205,5  D=gypsum fibre board  60  0,35  44,4  adequate  –  49(-3,-8)  33,8  106,0   awmopo01a-03  
B = multilayer wood wool composite claddingboard (WW-MW-WW)
04   4,0  120,0  94,0    218,0  D=without gypsum board lining
 
60  0,26  39,4  adequate  –  38(-1,-4)  19,9  73,5   awmopo01a-04  
B = mineral wool MW-PT