Building components- external wall - awropi22a Source: Knauf Insulation GmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update13.03.2017/hfa.plb
external wall: timber frame construction, not ventilated, with dry lining, with rendering

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 6.0 plaster   1,000  10 - 35  2000  1,130   A1
 100.0 MW-PT FKD-S C2 [036; R=110]   0,036  110  1,030   A1
 15.0 OSB   0,130  200  650  1,700   D
*   finger-jointed solid construction timber (60/..; e=625)  0,120  50  450  1,600   D
*   glass wool UNIFIT [037; R=14]   0,037  14  1,030   A1
  vapour barrier sd≥ 14m            
 50.0 Heraklith BM-W with 5 mm one-sided closure of pores coating  0,100  15  480  1,470   B
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  D* E* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   160,0  160,0  331,0    90  0,14  29,7  adequate  –  51(,)  19,0  64,8   awropi22a-00  
 
01   200,0  200,0  371,0    90  0,12  29,8  adequate  –  51(,)  21,0  67,0   awropi22a-01  
 
02   240,0  240,0  411,0    90  0,11  29,9  adequate  –  51(,)  23,0  69,3   awropi22a-02