Building components- intermediate floor - gdmtxa01a Source: Saint-Gobain Rigips Austria GesmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update21.09.2017/hfa.plb
intermediate floor: solid wood construction, suspended, dry, with filling

register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 20.0 Rigidur dry screed   0,200  19  1200  1,100   A1
*   Insulation material            
 60.0 bonded chippings   0,700  1500  1,000   A1
  trickling protection            E
*   cross laminated timber BBS 5 layer  0,130  50  470  1,600   D
 95.0 Direktabhänger            
 75.0 mineral wool [040; 18]   0,040  18  1,030   A1
 15.0 gypsum plasterboards Rigips RF or  0,250  10  900  1,050   A2
 15.0 gypsum fibre board Rigidur H   0,350  19  1200  1,100   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  B* E* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   10,0  130,0    null
 
90        49(2)  65(-4,-12)  12,2    gdmtxa01a-00  
impact sound absorbing subflooring MW-T [s'= 35MN/m³]
01   10,0  130,0    null
 
90        49(2)  65(-4,-12)  12,0    gdmtxa01a-01  
impact sound absorbing subflooring WF-T
02   10,0  147,0    null
 
90        47(2)  65(-4,-12)  15,1    gdmtxa01a-02  
impact sound absorbing subflooring MW-T [s'= 35MN/m³]
03   10,0  147,0    null
 
90        47(2)  65(-4,-12)  14,9    gdmtxa01a-03  
impact sound absorbing subflooring WF-T