Building components- internal wall - iwmxxi01b Source: Saint-Gobain Rigips Austria GesmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update22.06.2017/hfa.plb
internal wall: solid wood construction, with dry lining

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
*   cross laminated timber BBS   0,130  50  470  1,600   D
*   Exchangeable layer          
 50.0 mineral wool [040; 18]   0,040  18  1,030   A1
 25.0 gypsum plasterboards Rigips RF (2x12,5 mm) or  0,250  10  900  1,050   A2
 25.0 gypsum fibre board Rigidur H (2x12,5 mm)  0,350  19  1200  1,100   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  A* B* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   75,0  70,0  170,0  BBS 3 layer
B=Lattung (60/60) auf Schwingbügel 
30        –  49(-5,-12)  -13,5    iwmxxi01b-00  
 
01   75,0  85,0  185,0  BBS 3 layer
B=resilient channel 
30        –  61(-2,-7)  -9,1    iwmxxi01b-01  
 
02   100,0  70,0  195,0  BBS 5 layer
B=Lattung (60/60) auf Schwingbügel 
90        –  51(-6,-13)  -12,5    iwmxxi01b-02  
 
03   100,0  85,0  210,0  BBS 5 layer
B=resilient channel 
90        –  62(-2,-7)  -5,0    iwmxxi01b-03