Building components- pitched roof - sdmhzi01a Source: Saint-Gobain Rigips Austria GesmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update23.03.2017/hfa.plb
pitched roof: solid wood construction, ventilated, with dry lining, suspended

register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
  concrete roof tile /tiled roof      2100     A1
 30.0 spruce wood battens (30/50)  0,120  50  450  1,600   D
 50.0 spruce wood counter battens (minimum height 50 mm)  0,120  50  450  1,600   D
*   Exchangeable layer          
*   Insulation materialinsulation placed on top of the rafters            
  sealing sheet            
 100.0 cross laminated timber BBS 5 layer  0,130  50  470  1,600   D
 70.0 spruce wood battens (60/60; e=625) mounted on resilient clips  0,120  50  450  1,600   D
 50.0 mineral wool [040; 18]   0,040  18  1,030   A1
 15.0 gypsum plasterboards Rigips RF or  0,250  10  900  1,050   A2
 15.0 gypsum fibre board Rigidur H   0,350  19  1200  1,100   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  D* E* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   22,0  200,0  487,0  D=softboard [047; 200]  60  0,13  18,9  adequate  –  64(-5,-13)  15,0  176,0   sdmhzi01a-00  
E = softboard [040; 110]
01   22,0  240,0  527,0  D=softboard [047; 200]  60  0,11  18,9  adequate  –  64(-5,-13)  17,5  180,4   sdmhzi01a-01  
E = softboard [040; 110]
02     180,0  445,0  null
D=sarking membrane sd ≤ 0,3m 
60  0,13  18,9  adequate  –  61(-5,-12)  18,1  167,7   sdmhzi01a-02  
E = ?
03     200,0  465,0  null
D=sarking membrane sd ≤ 0,3m 
60  0,12  18,9  adequate  –  61(-5,-12)  20,5  169,7   sdmhzi01a-03  
E = ?