Building components- pitched roof - sdrhzi10a Source: Knauf Insulation GmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update22.03.2017/hfa.plb
pitched roof: timber frame construction, ventilated, with dry lining, directly

register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
  concrete roof tile or tiled roof      2100     A1
 30.0 spruce wood battens (30/50)  0,120  50  450  1,600   D
 50.0 spruce wood battens (min. 50 mm)  0,120  50  450  1,600   D
  sarking membrane sd ≤ 0,3m       1000     E
 24.0 spruce wood closed cladding without spacing of cladding boards  0,120  50  450  1,600   D
*   finger-jointed solid construction timber (80/..; e=800)  0,120  50  450  1,600   D
*   Insulation material            
  vapour barrier sd≥ 6m       1000     
 50.0 Heraklith BM   0,090  2 - 5  370  2,000   B
 10.0 plaster   0,700  10  1300  1,000   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  F* G* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   160,0  160,0  324,0  mineral wool
 
60  0,22  40,2  adequate  –  51(-3,-9)  -15,0  104,9   sdrhzi10a-00  
mineral wool Klemmplatte KP [038; R=30]
01   200,0  200,0  364,0  mineral wool
 
60  0,18  40,3  adequate  –  51(-3,-9)  -12,0  107,8   sdrhzi10a-01  
mineral wool Klemmplatte KP [038; R=30]
02   240,0  240,0  404,0  mineral wool
 
60  0,16  40,3  adequate  –  51(-3,-9)  -10,0  110,7   sdrhzi10a-02  
mineral wool Klemmplatte KP [038; R=30]
03   160,0  160,0  324,0  glass wool
 
60  0,22  39,7  adequate  –  51(-3,-9)  -18,0  102,6   sdrhzi10a-03  
glass wool UNIFIT [037; R=14]
04   200,0  200,0  364,0  glass wool
 
60  0,18  39,9  adequate  –  51(-3,-9)  -17,0  104,9   sdrhzi10a-04  
glass wool UNIFIT [037; R=14]
05   240,0  240,0  404,0  glass wool
 
60  0,16  40,0  adequate  –  51(-3,-9)  -15,0  107,2   sdrhzi10a-05  
glass wool UNIFIT [037; R=14]
06   160,0  160,0  324,0  glass wool - injected insulation
 
60  0,21  40,3  adequate  –  51(-3,-9)  -6,0  105,6   sdrhzi10a-06  
Supafil Timber Frame [034; R=35]
07   200,0  200,0  364,0  glass wool - injected insulation
 
60  0,17  40,3  adequate  –  51(-3,-9)  -1,0  108,7   sdrhzi10a-07  
Supafil Timber Frame [034; R=35]
08   240,0  240,0  404,0  glass wool - injected insulation
 
60  0,15  40,3  adequate  –  51(-3,-9)  4,0  111,7   sdrhzi10a-08  
Supafil Timber Frame [034; R=35]