Building components- compartment floor - tdmnxa01a
 
 


Cross-section of standard configuration
[Additional views]

note:
ATTENTION: In this case the L'nT,w was measured. Due to technical reasons the Ln,w-value is displayed. We apologise.


Last update23.03.2017/hfa.plb
compartment floor: solid wood construction, suspended, wet, with filling

register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 50.0 cement screed or anhydrite screed  1,330  50 - 100  2000  1,080   A1
  plastic separation layer   0,200  100000  1400  1,400   E
*   impact sound absorbing subflooring MW-T   0,035  68  1,030   A1
 50.0 fill   0,700  1800  1,000   A1
  trickling protection            E
*   solid wood (e.g. cross laminated timber); ≥ 134,0; at least 5-layers, top layer at least 26 mm)  0,130  50  500  1,600   D
 70.0 spruce wood battens (40/50) mounted on resilient clips  0,120  50  450  1,600   D
 50.0 glass wool [0,0040; R=16]   0,040  16  1,030   A1
 12.5 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 12.5 gypsum fibre board   0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  C* F* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   30,0  134,0  346,5    60  0,29  15,7  adequate  48()  58(,)  11,4  271,3   tdmnxa01a-00  
 
01   40,0  134,0  356,5    60  0,27  15,7  adequate  48()  58(,)  14,3  272,0   tdmnxa01a-01