Building components- compartment floor - tdmnxs01 Source: Saint-Gobain Rigips Austria GesmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update22.06.2017/hfa.plb
compartment floor: solid wood construction, without lining, wet, with filling

register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 50.0 cement screed   1,330  50 - 100  2000  1,080   A1
 40.0 impact sound absorbing subflooring MW-T [s'=6MN/m]   0,035  80  1,030   A2
 120.0 bonded chippings   0,700  1500  1,000   A1
  trickling protection            E
*   cross laminated timber BBS 5 layer  0,130  50  470  1,600   D
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  E* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   130,0  340,0    60  0,39  34,2  adequate  40(-1)  77(-2,-7)  11,7  344,4   tdmnxs01-00  
 
01   147,0  357,0    90  0,37  34,7  adequate  38(-1)  77(-2,-7)  14,5  352,4   tdmnxs01-01