Building components- compartment wall - twmxxo05a Source: Saint-Gobain Rigips Austria GesmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update22.06.2017/hfa.plb
compartment wall: solid wood construction, without dry lining, double-layer

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 12.5 gypsum plasterboards Rigips RF or  0,250  10  900  1,050   A2
 12.5 gypsum fibre board Rigidur H   0,350  19  1200  1,100   A1
 90.0 cross laminated timber BBS 3 layer  0,130  50  470  1,600   D
 30.0 gypsum fibre board Rigidur H (2x15 mm)  0,350  19  1200  1,100   A1
 50.0 mineral wool [040; 50]   0,040  50  1,030   A1
 50.0 air layer   0,000  1,008   
 30.0 gypsum fibre board Rigidur H (2x15 mm)  0,350  19  1200  1,100   A1
 90.0 cross laminated timber BBS 3 layer  0,130  50  470  1,600   D
 12.5 gypsum plasterboards Rigips RF or  0,250  10  900  1,050   A2
 12.5 gypsum fibre board Rigidur H   0,350  19  1200  1,100   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   365,0    60  0,30  39,7  adequate  –  70(-2,-8)  28,0  181,7   twmxxo05a-00