Building components- compartment wall - twmxxo06b
 
 


Cross-section of standard configuration
[Additional views]

Last update23.03.2017/hfa.plb
compartment wall: solid wood construction, without dry lining, double-layer

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 25.0 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 25.0 gypsum fibre board   0,320  21  1000  1,100   A2
 60.0 spruce wood batten mounted on resilient clips  0,120  50  450  1,600   D
 50.0 mineral wool [040; 13]   0,040  13  1,030   A2
 78.0 cross laminated timber (e.g. ≥ 78mm; 3-ply at least, surface layer at least 25mm)  0,130  50  500  1,600   D
 30.0 impact sound absorbing subflooring MW-T   0,035  68  1,030   A1
 78.0 cross laminated timber (e.g. ≥ 78mm; 3-ply at least, surface layer at least 25mm)  0,130  50  500  1,600   D
 50.0 mineral wool [040; 13]   0,040  13  1,030   A2
 60.0 spruce wood batten mounted on resilient clips  0,120  50  450  1,600   D
 25.0 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 25.0 gypsum fibre board   0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   356,0  A/I=2*12,5
 
90  0,20  24,2  adequate  –  61(,)  79,0  127,0   twmxxo06b-00