Building components- compartment wall - twrxxo01 Source: Knauf Insulation GmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update29.07.2016/hfa.plb
compartment wall: timber frame construction, without dry lining, single-layer

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 15.0 plaster   0,700  10  1300  1,000   A1
 50.0 Heraklith BM   0,090  2 - 5  370  2,000   B
  finger-jointed solid construction timber (60/100; e=625)  0,120  50  450  1,600   D
*   Insulation material            
 50.0 Heraklith BM   0,090  2 - 5  370  2,000   B
 15.0 plaster   0,700  10  1300  1,000   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  D* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   120,0  250,0    60  0,25  43,3  adequate  –  60(-1,-6)  -10,5  82,4   twrxxo01-00  
D = Heralan KP